Auditing two clinical apps against WCAG 2.2 AA

Auditing two clinical apps against WCAG 2.2 AA

Auditing two clinical apps against WCAG 2.2 AA

I audited both RadPass apps against WCAG 2.2 AA and fixed what failed through the design system.

I audited both RadPass apps against WCAG 2.2 AA and fixed what failed through the design system.

Role
Role

Founding Product Designer

Scope
Scope

Admin web app + Clinical tablet

Standard
Standard

WCAG 2.2 AA

7

issues found across both apps

2

colour tokens fixed ~280 uses

1 day

from scan to fix

01 · Context

Two apps. One accessibility standard.

Two apps. One accessibility standard.

RadPass tracks who is responsible for a radiotherapy machine. Physics leads use the web app, radiographers a shared wall tablet.

Hospitals increasingly ask how accessible a product is. I wanted an honest answer ready before anyone asked.

02 · The audit

I checked both apps against WCAG 2.2 AA.

I checked both apps against WCAG 2.2 AA.

I picked the 19 WCAG criteria that apply, scanned both apps with an AI agent, and verified every flagged value before changing anything.

Admin

Tablet

Pass

Failed, now fixed

Exception by design

Not yet tested

Keyboard criteria, touch-only device

03 · What failed

Most of what failed, most of us would never notice.

Most of what failed, most of us would never notice.

Each issue hit a screen-reader user, a low-vision user or a touch user.

Password

••••••••

Before: “button”

After: “Show password, button”

4.1.2 · Both apps

Screen readers just said “button”

Silent to screen readers. Fixed once in each shared component.

Updated 09:42

3.39:1

FAIL

Updated 09:42

4.6:1

PASS

Forgot?

3.92:1

FAIL

Forgot?

4.55:1

PASS

1.4.3 · Both apps

Grey and green text was too faint

Below 4.5:1. Darkened just enough to pass, same hue.

Before 32px

After 44px

Dashed ring = 24px AA minimum

2.5.8 · Tablet

Bigger close buttons

32px met AA. I went to 44px on 21 dialogs.

04 · Key decision

I fixed the colours once, not screen by screen.

I fixed the colours once, not screen by screen.

Both apps share one set of colour tokens, so one change fixes every screen in both.

2

token values

~280

places updated

2

apps in sync

Exception by design · Pinch-zoom on the tablet

Zoom is locked so a shared wall tablet cannot get stuck zoomed mid-handover. Instead, everything is large by default. Stated openly, not hidden.

The design system did the accessibility work. The audit just proved it.

05 · Colour vision

Then I tested the machine colours for colour blindness.

Then I tested the machine colours for colour blindness.

I simulated all 11 machine-state colours for four types of colour blindness. Every state already shows its name, so colour is never the only signal (WCAG 1.4.1). The goal was to make colour a better shortcut, not to make it carry the meaning.

Sage

Light Gray

before 0.8

Sage

Light Gray

after 6.2

As seen with green-blindness (deuteranopia)

1.4.1 · Both apps

Two machine states looked the same

With green-blindness, Sage and Light Gray were almost identical. Six colours re-tuned; the closest pair in the palette went from 0.8 to 2.0.

Sage

2.8:1

Sage

4.5:1

1.4.3 · Admin

State labels were hard to read

All 11 were at 2.5–3.9:1. All now pass 4.5:1.

Picked

as chosen

Picked

auto 4.5:1

1.4.3 · Both apps

New colours check themselves

Text auto-darkens to 4.5:1, so any colour a hospital picks stays readable.

06 · Status

Everything the scan found is fixed or explained.

Everything the scan found is fixed or explained.

Formally that is “partially compliant” until the remaining screens are tested. Those are listed below.

Fixed

  • Admin and tablet fixes live

  • Palettes in sync

  • State colours re-tuned and passing

Still to test

  • Signed-in and paired screens

  • Keyboard and screen-reader pass

  • Hospital-chosen colours

07 · Reflection

A week earlier I had merged the greys into one token scale. That housekeeping is why the fixes were cheap. The AI made the scan fast; checking its numbers made it trustworthy.

In a clinical product, a caption nobody can read is a caption nobody checks.

In a clinical product, a caption nobody can read is a caption nobody checks.

© Dimitra 2026

© Dimitra 2026

© Dimitra 2026

Create a free website with Framer, the website builder loved by startups, designers and agencies.